Lösungsansatz
RawSource supplies the base chemicals that go into these programs. We can help with product selection, grade matching, and sourcing from multiple origins for supply security.
Typical Treatment Workflow
1
Water & System Assessment
Characterize the water and the system — hardness, alkalinity, pH, TDS/conductivity, microbial load, and the metallurgy and temperatures of the equipment being protected.
2
Program & Chemistry Selection
Match coagulants, flocculants, scale and corrosion inhibitors, biocides, or pH adjusters to the water profile and discharge limits, factoring compatibility with any existing program.
3
Jar Testing & Dosing
Confirm coagulant and flocculant dose and feed point by jar test, set inhibitor and biocide treat rates, and size packaging (drums, totes, bulk) to consumption.
4
Monitoring & Control
Track residuals, turbidity, ORP, corrosion coupons, and effluent compliance, adjusting chemistry and dose as feedwater and load change.
Recommended Chemistries (6)
Citric Acid (Anhydrous, FCC Food Grade)
CAS 77-92-9
Säuren & Salze
Biodegradable chelant
Weak acid + chelant low-pH CIP that dissolves CaCO3 and iron/metal-oxide fouling while staying within polyamide membrane pH limits
Schmelzpunkt:153 °C (anhydrous) Siedepunkt:Decomposes Dichte:1.54 at 20 °C
Schnellansicht
Alle Details
Hydrochloric Acid
CAS 7647-01-0
Säuren & Salze
pH-Einstellung
1789 (HYDROCHLORIC ACID, SOLUTION) · Class Mineral acid to drop CIP pH for stubborn carbonate/metal scale where a stronger acid stage is needed
Schmelzpunkt:-115 °C (Melting point is -25 °C for a 39.17% w… Siedepunkt:51 °C at 760 mmHg Dichte:1.05 at 15 °C for 10.17% weight/weight solution
Schnellansicht
Alle Details
Caustic Soda (Sodium Hydroxide) Beads
CAS 1310-73-2
Säuren & Salze
Primäralkali zur pH-Erhöhung
1824 (SODIUM HYDROXIDE SOLUTION) · Class Raises high-pH cleaning stage to hydrolyze and lift organic foulants and biofilm off the membrane
Schmelzpunkt:318 °C Siedepunkt:> 130 °C at 760 mmHg Dichte:1.5 at 20 °C
Schnellansicht
Alle Details
Sodium Metasilicate Pentahydrate
CAS 10213-79-3
Säuren & Salze
pH-Einstellung
Alkaline builder that buffers the high-pH stage and disperses lifted soils, keeping them from redepositing on the element
Schnellansicht
Alle Details
Sodium Lauryl Sulfate (SLS)
CAS 151-21-3
Tenside
Reinigung / Entfettung
Anionic surfactant that wets the membrane and emulsifies organic/oil fouling during the alkaline CIP stage
Schmelzpunkt:204–207 °C Dichte:> 1.1 at 20 °C Solubility: < 1 mg/mL at 19 °C
Schnellansicht
Alle Details
Tetrasodium EDTA (EDTA Na4)
CAS 64-02-8
Amine & Amide
Chelatisierung / Sequestrierung
Tetrasodium EDTA chelates Ca/Mg/Fe in the alkaline CIP to strip metal-oxide and biofilm-bound hardness; a standard alkaline-CIP chelant a buyer expects here.
Schmelzpunkt:300 °C (decomposes) Dichte:6.9 lb/gal /Apparent density/ Solubility: Slightly soluble in ethanol
Schnellansicht
Alle Details
Verwandte Produktfamilien
● Verfügbar
Chelatbildner & Sequestriermittel
EDTA, DTPA und Citronensäure zur Härtesequestrierung und Eisenkontrolle
ChelatbildungSequestrierung
7 chemistries
Familie anzeigen
● Verfügbar
Chemikalien zur pH-Einstellung
Caustic soda, sulfuric acid, hydrochloric acid, and soda ash for pH control across all applications
pH-Einstellung
12 chemistries
Familie anzeigen