Membrane — Process Challenge

Químicos de limpieza (CIP) para membranas de ósmosis inversa

Los ensuciantes se acumulan en las membranas de ósmosis inversa y deben retirarse mediante limpieza in situ: una etapa de pH bajo para incrustación mineral y óxidos metálicos y una etapa de pH alto con tensioactivo y quelante para orgánicos y biopelícula, todo dentro de los límites de pH de la poliamida
Updated Jun 2026
Enfoque de solución

RawSource supplies the base chemicals that go into these programs. We can help with product selection, grade matching, and sourcing from multiple origins for supply security.

Typical Treatment Workflow
1
Water & System Assessment
Characterize the water and the system — hardness, alkalinity, pH, TDS/conductivity, microbial load, and the metallurgy and temperatures of the equipment being protected.
2
Program & Chemistry Selection
Match coagulants, flocculants, scale and corrosion inhibitors, biocides, or pH adjusters to the water profile and discharge limits, factoring compatibility with any existing program.
3
Jar Testing & Dosing
Confirm coagulant and flocculant dose and feed point by jar test, set inhibitor and biocide treat rates, and size packaging (drums, totes, bulk) to consumption.
4
Monitoring & Control
Track residuals, turbidity, ORP, corrosion coupons, and effluent compliance, adjusting chemistry and dose as feedwater and load change.
Recommended Chemistries (6)
Citric Acid (Anhydrous, FCC Food Grade)
CAS 77-92-9
Ácidos y Sales
Biodegradable chelant
Weak acid + chelant low-pH CIP that dissolves CaCO3 and iron/metal-oxide fouling while staying within polyamide membrane pH limits
Punto de fusión:153 °C (anhydrous)   Punto de ebullición:Decomposes   Densidad:1.54 at 20 °C
Vista rápida
Detalles completos
Hydrochloric Acid
CAS 7647-01-0
Ácidos y Sales
Ajuste de pH
1789 (HYDROCHLORIC ACID, SOLUTION) · Class
Mineral acid to drop CIP pH for stubborn carbonate/metal scale where a stronger acid stage is needed
Punto de fusión:-115 °C (Melting point is -25 °C for a 39.17% w…   Punto de ebullición:51 °C at 760 mmHg   Densidad:1.05 at 15 °C for 10.17% weight/weight solution
Vista rápida
Detalles completos
Caustic Soda (Sodium Hydroxide) Beads
CAS 1310-73-2
Ácidos y Sales
Álcali primario para elevar el pH
1824 (SODIUM HYDROXIDE SOLUTION) · Class
Raises high-pH cleaning stage to hydrolyze and lift organic foulants and biofilm off the membrane
Punto de fusión:318 °C   Punto de ebullición:> 130 °C at 760 mmHg   Densidad:1.5 at 20 °C
Vista rápida
Detalles completos
Sodium Metasilicate Pentahydrate
CAS 10213-79-3
Ácidos y Sales
Ajuste de pH
Alkaline builder that buffers the high-pH stage and disperses lifted soils, keeping them from redepositing on the element
Vista rápida
Detalles completos
Sodium Lauryl Sulfate (SLS)
CAS 151-21-3
Tensioactivos
Limpieza / Desengrase
Anionic surfactant that wets the membrane and emulsifies organic/oil fouling during the alkaline CIP stage
Punto de fusión:204–207 °C   Densidad:> 1.1 at 20 °C   Solubility: < 1 mg/mL at 19 °C
Vista rápida
Detalles completos
Tetrasodium EDTA (EDTA Na4)
CAS 64-02-8
Aminas y Amidas
Quelación / Secuestro
Tetrasodium EDTA chelates Ca/Mg/Fe in the alkaline CIP to strip metal-oxide and biofilm-bound hardness; a standard alkaline-CIP chelant a buyer expects here.
Punto de fusión:300 °C (decomposes)   Densidad:6.9 lb/gal /Apparent density/   Solubility: Slightly soluble in ethanol
Vista rápida
Detalles completos

¿Necesita ayuda para seleccionar el producto químico adecuado?

Nuestro equipo puede ayudar con la selección de grados, orientación sobre dosificación y abastecimiento multi-origen.

Solicitar Cotización All Water Treatment Problems
Solicitar Cotización